SFAW-100T-CS520-E-PNLK-PNVBA-# (8036886) Flow sensor

OT-FESTO060517

Exemplary representation: SFAW-100-CS520-E-PNLK-PNVBA-M# (8036885)   &   SFAW-100T-CS520-E-PNLK-PNVBA-# (8036886)
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Permission RCM mark,
c UL us - Listed (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directive,
acc. to EU-RoHS Directive
KC-mark KC-EMV
Material information RoHs compliant
Measured parameter flow,
temperature
Flow direction P1 -> P2,
Uni-directional
Measurement process temperature: PT1000,
Flow: Vortex
Flow measurement range starting value [l/min] 5,0
Flow measurement range end value [l/min] 100
Operating pressure [bar] 0 to 12
Information about operating pressure max. 12 bar at 40°C,
max. 6 bar at 100°C
Operating medium Fluid media,
Neutral liquids,
Water
Information about operating and control medium Media compatibility to the media contacting materials must be guaranteed
Medium temperature [°C] 0 to 90
ambient temperature [°C] 0 to 50
Nominal temperature [°C] 23
Accuracy flow value ±2 %FS for flow <= 50 %FS,
± 3 % o.m.v. for flow >= 50 %FS
Accuracy temperature in ± °C [°C] 2
Repeatability flow value < ±0.5 %FS for flow <= 50 %FS,
< ±1 % o.m.v. for flow >= 50 %FS
Temperature coefficient clamp in ± %FS/K type ±0,05%FS/K
Control output 2 x PNP or 2 x NPN switchable
Switch function Window comparator,
Threshold comparator,
Freely programmable
Switching element function Opener/closer switchable
Max. output current [mA] 100
Analogue output 0 - 10 V,
4 - 20 mA,
1 - 5 V
Flow characteristic curve starting value [l/min] 0
Flow characteristic curve end value [l/min] 100
Max. load resistance current output [Ohm] 500
Min. load resistance voltage output [kOhm] 15
Short circuit resistance yes
Overload resistant Available
Report IO-Link
IO-Link, report Device V 1.1
IO-Link, profile Smart sensor profile
IO-Link, function classes Teach channel,
Diagnosis,
Identification,
Binary data channel (BDC),
Process data variables (PDV)
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, SIO mode support yes
IO-Link, port type A
IO-Link, process data width OUT 0 Bytes
IO-Link, process data width IN 5 Bytes
IO-Link, process data contents IN 1 bit BDC (volume monitoring),
14 bit PDV (flow measurement),
1 bit BDC (temperature monitoring),
14 bit PDV (temperature measurement),
2 bit BDC (flow measurement)
IO-Link, service data unit IN 32 bit Volumenmesswert
IO-Link, minimum cycle time 5 ms
IO-Link, data memory needed [Byte] 500
Operating voltage range DC [V] 18 to 30
Reverse polarity protection for all electrical connections
Electrical connection M12x1,
5 pin,
Plug straight,
A-coded
Max. line length 30 m,
20 m For OK link operation
installation position arbitrary
Fluid connection Terminal connection DIN 32676 DN20
Product weight [g] 280
Housing material PA reinforced
From medium contacting materials EPDM (perox.),
ETFE,
stainless steel,
PA6T/6I reinforced
Presentable unit(s) US gal,
US gal/min,
cft,
cft/min,
l,
l/h,
l/min,
m3,
°C,
°F
Protection category IP65
Corrosion resistant class KBK 3 - severe corrosion stress
Temperature measurement range stating value [°C] 0
Temperature measurement range end value [°C] 90
Temperature characteristic curve starting value [°C] 0
Temperature characteristic curve end value [°C] 100
OT-FESTO060517
{{ $t('shop.all.gewicht') }} 280 g / pcs
{{ $t('shop.display.artikel.zollwarennummer') }} 90261021
{{ $t('shop.all.hersteller') }} Festo
{{ $t('shop.all.dokumente') }}

 
{{ $t('shop.all.unverbindliche_richtwerte') }}
{{ $t('shop.all.spaetbestellservice') }}
{{ countdownAsString }} {{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.